Water meter testing

Water meter repair

Water meter calibration

Water meter replacement / new installation

Complaint resolution

On-site and in-shop meter rebuilding and calibration

Update meters for integration into SCADA systems

New meter sales and parts

Sales of re-manufactured current models and components

Special applications

Reports on demand

Meter servicing on-site is performed employing the "In-Line" method. The meter is isolated and test water discharge fittings are temporarily installed. The inlet valve is opened to allow water to pass through the subject meter and then through the test meter. The collected registration on the subject meter is compared to the test meter to obtain an unadjusted accuracy result. The unadjusted accuracy result is amended by the test meter accuracy factor to reach a true adjusted accuracy result. Coulter uses Sensus Metering Systems 125-W and W-1250 field testers. These units have been designed specifically for the task and feature electronic re-settable registers providing the maximum accuracy calculations. Each service vehicle carries spare calibrated measuring modules required in the event of an equipment failure. Test meter modules are tested and calibrated weekly to ensure the highest standard of performance with no interruption in field service. Test flows and quantities are pursuant to AWWA guidelines or the manufacturer’s claims, whichever is the more stringent.

Meters serviced in our shop are flow tested into measured calibration tanks employing the "gravimetric" method whereby the water discharged into the calibration tank is weighed.

Electronic metering devices (electromagnetic flow meters etc.) are tested and verified employing the respective manufacturers’ approved equipment. This equipment must be returned to the manufacturer annually for re-certification. Wherever possible, in addition to the electronic testing, wet runs are performed as a secondary verification. Wet runs are conducted using the "In-Line" method.

Where meters are equipped with contact closures or pulse outputs, while the flow test is being performed on a registered throughput basis, a counter is employed to confirm the outputs. Similarly, where 4-20mA loops are present, this output is checked using "Fluke Multimeter" devices.

Meter service reports are generated via an "Access" management system featuring up to 10 years history per individual location. These are detailed reports providing before and after accuracy results, meter details, locations and contact references. In addition, our system has a re-date field used to schedule future scheduled maintenance.